Radar level transmitter supplier factory with kaidi86.com: In this paper, there are three situations that lead to the radar level meter measurement value jump, respectively, closed metal cover, condensation on the antenna, power supply power supply is insufficient. In fact, the radar level meter measurement value jump belongs to a relatively common problem, leading to the emergence of this problem for a number of reasons, the emergence of problems in a timely manner to find the cause and solve the problem is the most important. Liquid level is the height of the liquid level in a sealed container (pool) or an open container (pool). In addition, liquid level measurement is divided into two categories: continuous measurement and level measurement. Read additional information at radar level transmitter suppliers.
Advanced Radar Level Measurement: The constant progress of innovation continues to push the limits of radar level measurement, propelling this technology into areas of capability and pertinence. As industries undergo transformations and integrate the Industrial Internet of Things (IIoT) into their operational processes radar devices have evolved to meet these changing demands. Integration with IIoT- Leading the Way to Industry 4.0 One of the transformative developments in radar level measurement is the seamless integration of Industrial Internet of Things (IIoT) capabilities into radar devices. These radar sensors equipped with IIoT features have become important components in Industry 4.0 initiatives ushering in an era where data driven excellence prevails in operations.
Application conditions, application conditions generally include calm liquid level, slightly fluctuating surface, turbulent surface, with stirring, with foam and so on. The more complex the conditions, the more interference echoes, and the smaller the actual measured range. In a complex environment, a precision radar with strong ability to deal with interference echoes or an antenna with a larger size should be selected.
Measuring principle of radar water level meter: The radar level gauge adopts the working mode of transmitting-reflecting-receiving. The electromagnetic wave emitted by the antenna is reflected by the surface of the measured object and then received by the antenna. After measuring the distance from the water surface to the radar antenna, the elevation of the water surface can be calculated according to the elevation of the radar antenna. The radar water level meter adopts pulse wave technology with low power consumption. It can be powered by two-wire 24 VDC, 485 interface output, or can be directly powered by 12 VDC, SDI-12 interface output, with high accuracy and wider application range.
For more accurate measurement in deaerators, magnetrol guided wave radar (GWR) is a preferred option. Since its performance and accuracy are not contingent on the specific gravity and/or inference, it can provide reliable measurements in all situations, including the difficult and turbulent process conditions of deaerators and feedwater heaters. In addition, GWR does not require external inputs or calibration to achieve specified performance. This effectively eliminates the introduction of errors during the calibration process or from external sources, i.e., pressure and temperature. With this high level of accuracy, operators can trust that their deaerators will be well controlled.
In the process of cement production, material level detection and material level alarm control play an important role from mining and crushing to storage and packing of finished cement. But because of the complex working conditions of cement plant, radar level meter has no small difficulty in measuring. Today, I would like to talk with you about specific difficulties and solutions. First cement plant material for measurement in the dust under the condition of particularly large, especially some pneumatic feed bin, involves the kinds of materials, material particle size is differ, dielectric constant is different also, such as broken limestone, raw meal, clinker, fly ash, coal, cement, the level of the bunker, it is very difficult to accurately measure Especially fly ash bin with low dielectric constant.
With emphasis placed on customer satisfaction, innovation, product development and overall business transformation, the company continued to innovate and expand with each passing year. KAIDI has successfully achieved global recognition, obtaining the leading position as Asia’s top process automation sensor manufacturer. In the past 5 years, the company has undergone tremendous growth and development – flourishing internationally and providing customers worldwide with the best customized solutions for process automation. Read even more information on https://www.kaidi86.com/. Kaidi Energy is a level gauge manufacturer which more than 20 years of industrial automation experience.
The radar level gauge works by electromagnetic waves. Its working principle is to measure the specific liquid level by transmitting electromagnetic waves to the measured target. After the electromagnetic waves are emitted, they are reflected by the medium. For the radar level gauge, its key function is to ensure that it can transmit magnetrol guided wave radar signals smoothly. In our industrial production site, interference often occurs, so which interference sources will affect the measurement of the radar level gauge? let’s see.
Under many operating conditions, ultrasonic level meter and radar level meter are commonly used. Some users are very entangled in the choice of these two level meter and do not know how to choose. Today, let’s talk about the principles and selection principles of these two types of level meter . Principle and selection principle of ultrasonic level meter. Working principle: The ultrasonic pulse probe emits a beam of ultrasonic pulses to the measured medium, and the sound wave is reflected by the liquid surface. The distance between the liquid levels is measured by measuring the time difference between the emission and reflection of the sound waves. Since the ultrasonic level gauge is not a liquid, it can be used to measure corrosive, non-volatile and non-foaming places.
Product features: Large display range, wide range of use, suitable for low temperature, medium temperature, high pressure occasions. It can be matched with remote transmitter output 4-20MADC standard signal to realize remote display of liquid level guage. It can also be matched with liquid level switch to realize liquid level control. Generally speaking, the material level feedback is inaccurate and untimely, which is very prone to explosion events, and there is a greater safety risk. Therefore, the requirements for the radar level meter are very high, but the radar level meter often has abnormal material level jumps or falls, or even crashes, resulting in large errors in material level measurement, which brings trouble to production and sales.