Turbine mass flow meter manufacturer 2025: Useful for Gases and Liquids: Mass flow meters can be used for both gases and liquids. They are commonly used in applications where precise control over mass flow is necessary, such as chemical processing, gas distribution, and HVAC systems. Because mass flow meters measure mass directly, they are less affected by temperature and pressure variations. They are frequently used when the fluid’s temperature and pressure are subject to significant fluctuations. Find more info on coriolis flow meter.
Is the scope of application of turbine flow meter very wide? Suitable for more industries: This product is suitable for power generation, petrochemical, metallurgy and coal mining industries. Can measure more media: Because it can measure oil, organic liquid, inorganic liquid, liquefied gas, natural gas, coal gas and other media, the sales volume of the product will also be higher. The quality of professional manufacturers is more guaranteed: At present, only manufacturers with advanced technology and strong strength can produce products with more reliable quality. Measurement of some corrosive liquids, such as sulfuric acid, hydrochloric acid, nitric acid, acetic acid and other acids and various chemical solutions.
It is the existence of domestic brands that has forced the prices of foreign brands to drop by 1/2-2/3 in recent years. The production and R&D investment of natural gas turbine meter is relatively large, and the prices of enterprises with certain strength will also be higher in domestic brands. But even then, they are only about half the price of high-end international brands. Therefore, it is recommended that users choose carefully on the basis of comprehensive consideration of their respective use requirements and procurement costs. Don’t pursue low prices too much, nor do you need to pursue imported brands inappropriately.
Turbine Flow Meter has the characteristics of high accuracy, good repeatability, convenient installation and maintenance, and simple structure. Liquid flows through the turbine casing, causing the internal rotor to rotate. When the rotor rotates, an electrical signal is generated in the pickup coil. This signal is converted to engineering units (liters, cubic meters, gallons, etc.) on the applicable local display. Optional accessory modules can be used to export signals to other devices. Make sure the vortex flow meter model meets your specific needs. For your future reference, if this information becomes unreadable on the turbine, it may be useful to record it on the nameplate of the manual. See the nameplate for your custom product specifications. Discover extra details on https://www.bjssae.com/.
Beijing Sincerity has developed over years to manufacture the Coriolis Mass Flow Meters industries. Through continuous research, development and transformation, we have become the leader of the Coriolis Mass Flow Meters industries in China. The Coriolis measuring principle is used in a wide range of different branches of industry, such as the life sciences, chemicals, petrochemicals, oil and gas, food, and – no less importantly – in custody transfer applications. Coriolis flowmeters can measure virtually all fluids: cleaning agents, solvents, fuels, crude oil, vegetable oils, animal fats, latex, silicon oils, alcohol, fruit solutions, toothpaste, vinegar, ketchup, mayonnaise, gases or liquefied gases.
It has been considered in the design that the steam becomes superheated, or it is difficult to determine which state it is in, or sometimes it is superheated and sometimes saturated, so the temperature and pressure compensation is adopted, and the above phase change has no effect on the measurement results. Considering saturated steam in the design, and adopting pressure compensation, the above-mentioned phase change will bring about a small error, that is, the compensation error caused by the density difference corresponding to the difference between the superheated steam temperature and the saturated steam temperature. The design is based on saturated steam, but temperature compensation is used, that is, the temperature of superheated steam is used as the saturation temperature to check the density table, which will generally cause large errors.
China Capital technology group invested in the SINOPEC automation instrument department of Beijing institute of chemical industry. Beijing shouke shí huà automatic equipment Co., LTD (Beijing Sincerity’s predecessor) was officially established. “Shí huà” is the Chinese words from SINOPEC. Sincerity officially switched from a national company to joint-stock company. Beijing shouke shí Huá ( which is Beijing Sincerity Automatic Equipment Co., Ltd now ) was officially established. The Chinese pronunciation of “shí Huá “ and “ shí huà” are very close to each other. The 1st generation coriolis mass flow meters were officially launched. The coriolis mass flow meters are with all discrete components, little chips and LED digital display.